HBX Mode:
• Standsforhigh battery transfer
• Isusedwithgrid-connectedFXSeriesInverter/ChargersthathaveutilitypowerastheirAC
input
• Isamodeprimarilyusedinapplicationsthathaveenoughrenewableenergy(RE)power
production to meet the needs of the loads most of the time
• AllowstheFXtoconnecttoanACsourceifthebatteryvoltagehasfallenbelowaprogram-
mablesetpointforausercongurableamountoftime(MATEwillthenallowtheFXto
remain connected to the AC source until the battery voltage has risen above a second set
pointforaprogrammableamountoftime)
e MATE detects when the battery is truly low and needs charging as opposed to a sudden
andmomentarydropcausedbyasizabledemandforpowerfromadevicesuchasamotor.
Atthesetimes,theMATEdirectstheFXtouseACpoweruntilthebatteryisfullycharged
again. e user programs in the amount of time a battery can be below the low voltage and
theamountoftimeaerit’sfullychargedbeforetheMATEstartsissuingitscommands.e
MATE uses these times to switch back and forth between AC and battery power. Additionally,
inHBXmode,theFXchargingfunctioncanbeshutotoallowthealternativeenergysource
to recharge the batteries while the loads are powered by the utility grid.
MAIN-----------------------------------
8:25:04A
SUM STATUS SETUP ADV
ADV/PASSWORD---------------
enter the password
132
ENTER INC DEC EXIT
ADV/SETTINGS/WARNING
changes made could
adversely affect
system performance
ADV----------------------------------
choose a product:
FX CC DC MATE
ADV/MATE/HBX-------------------
hbx-use 24.0 vdc
griduse point
DOWN ADV INC DEC
ADV/MATE/PG1--------------------
choose category
HBX GRIDUSE AGS PG2
Press <INC>until141,thenpressenter
ADV/MATE/HBX --------------------
hbx-use 01.0 hrs
grid delay
DOWN UP INC DEC
ADV/MATE/HBX -------------------
hbx-drop 01.0 hrs
grid delay
DOWN UP INC DEC
ADV/MATE/HBX --------------------
hbx-drop 26.0 vdc
grid setpoint
DOWN UP INC DEC
ADV/MATE/HBX ---------------------
end of HBX menu
UP TOP ADV
Press <INC> and <DEC> so
keys as needed to change set
points
ADV/MATE/HBX ---------------------
ac input
control
DOWN UP CHANGE